Technical Data

DC-Side Parameters

AC-Side Parameters

System Parameters

Cell

280Ah

AC Low-Voltage Side Rated Voltage

AC400V


Cooling System

Variable Frequency + Liquid Cooling

Pack Configuration

1P52S

AC Rated Power

100 kW

Cooling System

Variable Frequency + Air Cooling

Voltage Range

832V-949V

Power Factor

>0.99


Fire Protection System

Perfluorohexanone + Combustible Gas Detection + Explosion-Proof Valve + Water

Charge/Discharge Rate

0.5P/100kW

Reactive Power Adjustable Range

-1~+1


Compliance Standards

UN38.3, UL1973, UL9540A, IEC62619, GB/T 36276

Depth of Discharge (DOD)

90%

Grid Frequency

47.5~52.5

Communication Interface

RS485, CAN, Ethernet

Communication Interface

RS485, CAN

AC Current THD

≤3%

Communication Protocol

Modbus-TCP/RTU/CAN 2.0

Communication Protocol

Modbus-TCP, CAN 2.0

Long-term Overload Capability (10 min)

1.1×AC Rated Power

Weight

26 tons

Cell Cycle Life

6000 cycles

Short-term Overload Capability (1 min)

1.2×AC Rated Power

Dimensions

1300×1350×2200 mm

Storage Temperature

-40°C to 60°C , -10°C to 35°C (6 months), Humidity 5%-95%

Isolation Method

None

Operating Temperature Range

-30°C to 55°C (Operation below 20°C requires prior notice)

System Configuration

1P260S

 

 

Operating Humidity Range

0% to 95%

 

 

 

Get a Quote

What products are you interested in?



Get a data sheet